- 意大利Chemitec
- 意大利賽高SEKO計(jì)量泵
- 意大利SEKO儀器儀表
- 意大利SEKO氣動(dòng)隔膜泵
- FLOWLINE液位計(jì)
- 瑞士梅特勒mettler
- 英國(guó)Williamson蠕動(dòng)泵
- E+H
- 德國(guó)LUTZ魯茨
- 美國(guó)G+F儀表閥門控制器
- 法國(guó)(KIMO)凱茂環(huán)境測(cè)量及...
- 美國(guó)FTI插桶泵
- 進(jìn)口氣動(dòng)隔膜泵
- 易威奇計(jì)量泵
- 米頓羅計(jì)量泵
- 普羅名特計(jì)量泵
- 帕斯菲達(dá)計(jì)量泵
- 上泰儀器儀表
- 哈納儀器儀表
- 羅斯蒙特儀表
- Hamilton 漢密爾頓
LPK2M4B-KTC1,LPK2M4B-KTC1,LPB2M4B-KTC1,LPB2M4B-KTC1,LPD3M4B-KTC1,LPD3M4B-KTC1,LPF4M4B-KTC1,LPF4M4B-KTC1,
LPH4M4B-KTC1,LPH4M4B-KTC1,LPD4M4B-KTC1,LPD4M4B-KTC1,LPG4M4B-KTC1,LPG4M4B-KTC1,LPK5M4B-pTC3,LPK5MB-KTC3,
LPH5MB-PTC3,LPH5MB-KTC3,LPH5MB-KTC3,LPA3M4B-KTC1,LPA3M4B-KTC1,LPK3M4B-KTC1,LPK3M4B-KTC1,LPB4M4B-KTC1,
LPB4M4B-KTC1,LPE4M4B-PTC3,LPE4M4B-KTC3,LPG5M4B-PTC3,LPG5M4B-KTC3,LPH6M4B-PTC3,LPH6M4B-KTC3,LPK7M4B-PTC3,LPK7M4B-KTC3,LPH7M4B-PTC3, LPH7M4B-KTC3,LVH7MB-WTSK*,LPJ8MB-PTCB*,LPH8MB-PTCB*
?所有型號(hào)標(biāo)配: 三功能閥,注射閥, 底閥, 進(jìn)出口軟管(標(biāo)*的型號(hào)無(wú)三功能閥) ?電源:220V*大功率:300W
?配五功能閥需單獨(dú)訂貨
?PVC泵頭可選,價(jià)格與PVDF泵頭材質(zhì)相同.
美國(guó)帕斯菲達(dá)pulsafeeder電磁計(jì)量泵LPB2MB-KTC1,加藥泵流量調(diào)節(jié)方式:4-20mA+信號(hào)控制,泵頭材質(zhì):PVDF
*手動(dòng):頻率,沖程同時(shí)可調(diào) *流量0.5-95升/小時(shí),壓力2-21Bar *自動(dòng):可選4-20mA4-20mA信號(hào),液位信號(hào)接收功能 *21種機(jī)型
美國(guó)帕斯菲達(dá)pulsafeeder電磁計(jì)量泵LPB2MB-KTC1,加藥泵流量調(diào)節(jié)方式:4-20mA+信號(hào)控制,泵頭材質(zhì):PVDF
6.1日常維護(hù)
·日常檢查泵的實(shí)際運(yùn)行狀況。查找有無(wú)異常噪聲、過(guò)度振動(dòng)、流量低、壓力輸出低或高溫等現(xiàn)象[泵以*高行程速率穩(wěn)定運(yùn)行時(shí),泵殼溫度可達(dá)到160F(70℃)]。
·要獲得*佳性能,插裝閥應(yīng)每隔6-12個(gè)月更換一次。根據(jù)用途的不同,可能要求更頻繁地更換。
這種情況下,實(shí)際操作經(jīng)驗(yàn)是*好的指南。
·閥座和閥球的反復(fù)短壽命老化通常說(shuō)明需要檢查選擇用于該用途的濕材料的適用性。若需要指導(dǎo),請(qǐng)與供應(yīng)商聯(lián)系。
·檢查接頭周圍有無(wú)泄漏,或老化管道所產(chǎn)生的泄漏,例如:暴露于直射陽(yáng)光的標(biāo)準(zhǔn)白色半透明排放管。采取適當(dāng)措施,如擰緊接頭或更換部件來(lái)修正泄漏。
·**泵上的污垢/碎屑,這類物質(zhì)會(huì)產(chǎn)生絕熱作用,導(dǎo)致泵的溫度過(guò)高。·如果泵停止運(yùn)行一個(gè)月或以上,應(yīng)清洗泵頭/閥門組件,方法是泵送淡水約30分鐘。如果在這種“清洗運(yùn)行”后泵不能正常運(yùn)行,則需更換插裝閥組件。
PULSAtron Series E Plus Metering Pump
504 GPD @ 20 PSI, 230 VAC4-20 mA Input with Dual Manual Control and Stop Function Input
Stroke frequency control via 4-20 mA signal input, manual stroke length control. Stroke frequency is manually adjustable when in local control. Includes stop function input.
General Description
Pulsafeeder PULSAtron Series E Plus chemical metering pumps are positive displacement, diaphragm type pumps. Output volume is adjustable while pumps are in operation from zero to maximum capacity. The PULSAtron Series E Plus contains a highly reliable timing circuit as well as circuit protection against voltage and current upsets. This pump features solenoid protection by thermal overload with auto-reset. The Series E Plus guided check valves, with their state-of-the-art seat and ball designs, provide precise seating, and excellent priming and suction lift characteristics. Our timing circuit is highly reliable and, by design, virtually unaffected by temperature, EMI and other electrical disturbances.
Pump Controls
Adjustment is by means of readily accessible dial knobs, one for changing stroke length and the other for changing stroke frequency. Both knobs are located opposite the liquid handling end. Automatic control via 4-20mA DC and stop function inputs. Auto-Off-Manual switch.
Drive Assembly
The pump drive is totally enclosed with no exposed moving parts. Electronics are housed in chemical resistant enclosure at the rear of the pump for maximum protection against chemical spillage. Average electrical power consumption is 130 Watts.
Materials of Construction
See Specifications tab. Chemical metering pump housing shall be of chemically resistant PBT thermoplastic. All exposed fasteners are stainless steel. Valve seat and seal ring are renewable by replacing the cartridge valve assembly.
Pulsafeeder PULSAtron Series E Plus Chemical Metering Pump - Key Features
- Manual Control by on-line adjustable stroke rate and stroke length.
- Highly Reliable timing circuit.
- Circuit Protection against voltage and current upsets.
- Panel Mounted Fuse.
- Solenoid Protection by thermal overload with auto-reset.
- Water Resistant, for outdoor and indoor applications.
- Indicator Lights, panel mounted.
- Guided Ball Check Valve Systems, to reduce back flow and enhance outstanding priming characteristics.
- Few Moving Parts and Wall Mountable.
- Safe & Easy Priming with durable leak-free bleed valve assembly (standard).
- Reliable metering performance.
- Rated "hot" for continuous duty.
- Leak-free, sealless, liquid end.
Includes:
A weighted foot valve/strainer assembly, a 1/2" NPT male injection fitting/back pressure check valve assembly, 4' suction tubing, 8' discharge tubing and Owners Manual